GW Instek introduces the brand new high precision LCR meter – LCR-6000 series, which, with five models, has a test frequency range extending from 2kHz/20kHz/100kHz/200kHz/300kHz (maximum) and with 0.05% basic accuracy. The compact size design, 2U height and 1/2 rack, is one of the practical features of the series which is the optimum space saver suitable for either bench top or system rack. The compacted LCR-6000 series with abundant features is absolutely the excellent tool for R&D, production test, IQC, etc. on implementing each test stages for passive components.

    LCR-6300 10Hz ~ 300kHz High Precision LCR Meter

    3.5” color LCD

    Consecutive test frequency

    Basic accuracy : 0.05%

    Measuring speed up to 25ms (max.)

    Full frequency range or spot OPEN/SHORT

    16 major/secondary parameter measurement combinations and two additional monitoring parameters(maximum four different parameters can be shown simultaneously)

    DCR measurement and internal D.C. bias voltage (±2.5V)

    PASS/FAIL judgment

    Auto Level Control (ALC) function

    BIN function provides 9BIN and 1AUX, totally 10 BIN

    10 steps listed tests to select different frequency, voltage and current criteria

    Standard interface : RS-232C, Handler and USB storage

The LCR-6000 series provides rich functionalities with the compact size. First of all, the entire series adopts 3.5-inch color LCD and features opulent display parameters. In addition to simultaneously displaying setting criteria and measurement results, the series increases two additional monitoring parameters. In other words, there are four parameters, primary/secondary and two monitoring, simultaneously shown on the screen that tremendously enhances the measurement efficiency. The enlarge display mode not only emphasizes the measurement results, but also provides PASS/FAIL judgment to facilitate a rapid and convenient test result.

Convenience is one of the unique features. The LCR-6000 series comes equipped with two zero methods, which are full frequency range and spot. Users, without turning off the power and changing test fixture, can freely change frequency within the provided frequency range to conduct measurements. By so doing, tremendous time can be saved from repeatedly executing zero operation. Additionally, frequency range of the series is consecutive that allows users to input precise frequency value to conduct the most genuine test on components.

The LCR-6000 series also features diverse ancillary measurements to meet the measurement requirements of different materials. For instance, the series provides the automatic level control (ALC) function to satisfy the test voltage requirement of MLCC. For inductive component measurements, the series provides the adjustable test current function and the D.C. resistance measurement function. The optional external bias current adapter (±2.5A) is to satisfy the measurement requirements. With respect to the D.C. bias voltage test for capacitive components requirements, the series allows users to conduct verification measurement on materials by its internal ±2.5V adjustable voltage or via an optional external bias voltage adapter (±45V). Furthermore, 10 steps of listed test functionalities allow users to set testing parameters (either by frequency, or voltage, or current) for each step based on users’ requirements in order to observe the trend of DUT characteristics. The LCR-6000 series has 10 memory sets defined by panel setting criteria to facilitate users in selecting test criteria and saving time in repeated settings. 10,000 measurement result storage capability can easily record measurement results instantaneously. The USB host allows easy access to recorded results without connecting the series to the PC. The USB host also allows USB to retrieve and save screen so as to assist users in compiling setting guidelines.

For the external control, the LCR-6000 series provides handler interface and collocates with its measurement sorting function (9BIN, AUX: 1BIN) to facilitate the connection with sorting machine so as to sort out the materials. For remote control and measurement result retrieval requirements, the LCR-6000 series provides RS-232Cto assist setting control or measurement result retrieval via the PC commands. Additionally, the free PC software gives users an instant tool to store measurement results that saves time in developing programs.

The brand new compacted LCR-6000 series can effectively improve the limitation of space. Diverse measurement functionalities and display methods are making the series the high CP ratio choice in meeting the requirements of R&D, component assessment for engineering departments, category sorting requirements for component production, and IQC for verification on component specifications.

Consecutive frequency and Convenient zero function

The LCR-6000 series, within the provided frequency range, features consecutive and adjustable frequency capability which allows users to conduct measurement and analysis on components with the most genuine frequency requirements. For OPEN/SHORT fixture compensation function, the LCR-6000 series is equipped with full frequency range zero and spot zero selections. After executing full frequency range zero, users, under the conditions of not turning off the power and not changing test fixture, can freely change test frequency for the LCR-6000 series to execute component measurements that tremendously saves time in repeatedly zeroing test fixture after changing frequency.

Rich and diverse information display

The measurement result display of the LCR-6000 series not only reveals primary and secondary measurement parameters but also includes two monitoring parameters. Therefore, four DUT related parameters can be simultaneously shown on the display screen to save time if repeated measurements are required. With respect to display screen, the LCR-6000 series features diverse display to meet users’ observation requirements. For instance, MEAS display shows setting parameters and measurement results at the same time; ENLARGE display focuses on measurement results and PASS/FAIL judgment is available, which is conducive to assist engineers to swiftly obtain the validity of measurement results.

In The Box

    Safety Sheet x 1

    Power Cord x 1

    Test Fixture LCR-06Ax 1

    CD x1(User manual / PC software)

Manufacturer Specs

Instek LCR-6000 Series High Precision LCR Meter Specifications
TEST FREQUENCY
LCR-6300: 10Hz~300kHz(±0.01%) (4 digits resolution)
LCR-6200: 10Hz~200kHz(±0.01%) (4 digits resolution)
LCR-6100: 10Hz~100kHz(±0.01%) (4 digits resolution)
LCR-6020: 10Hz~ 20kHz(±0.01%) (4 digits resolution)
LCR-6002: 10Hz~ 2kHz(±0.01%) (4 digits resolution)
OUTPUT IMPEDANCE
30Ω / 50Ω / 100Ω selectable
BASIC ACCURACY
Slow / Med 0.05%
Fast 0.1%
TEST SPEED
FAST:25ms / MED:100ms / SLOW:333ms
TEST SIGNAL LEVELS
Voltage 10.00mV- 2.00V (±10%) CV :10.00mV- 2.00V(±6%)
Current 100.0uA- 20.00mA (±10%) CC :100.0uA- 20.00mA(±6%) (@2VMax)
DC BIAS
Internal
DISPLAYRANGE
R, X, |Z|
G, B, |Y|
L
C
D
Q
θd
θr
DCR
λ%
0.00001O ~ 99.9999MO
0.01nS ~ 999.999S
0.00001uH ~ 9999.99H
0.00001pF ~ 9999.99mF
0.00001 ~ 9.99999
0.00001 ~ 99999.9
-179.999° ~ 179.999°
-3.14159 ~ 3.14159
0.00001Ω ~ 99.9999MΩ
-99999% ~ 99999%
TEST MODE
16 Combinations Cs-Rs, Cs-D, Cp-Rp, Cp-D, Lp-Rp, Lp-Q, Ls-Rs, Ls-Q,
Rs-Q, Rp-Q, R-X, Z-θr, Z-θd, Z-D, Z-Q, DCR
Monitor parameter (2 selectable) Z, D, Q, Vac, Iac, λ, λ%, θr, θd, R, X, G, B, Y
LISTED MODE
10 steps
BIN FUNCTION
Comparator (9BIN,AUX:1BIN)
MEMORY
INT – panel setting 10 file name
INT – measured data 10000 Data(.csv)
USB storage 10 file name for setting, 9999 file name for data, 999 Log file for LCD screen
OTHER FUNCTION
Auto Level Control (ALC) ON/OFF
Average 1~256 times
Trigger INT / MAN / EXT / BUS
Delay 0ms~60s
Judgment PASS / FAIL
Auto LCZ ON / OFF
Screen Capture Saving in to USB (Bmp form)
DISPLAY
3.5’LCD, RGB color (320×240)
INTERFACE
RS-232(SCPI), Handler, USB Host
POWER SOURCE
AC 90V-250V, 50-60Hz, Max. 30VA
DIMENSION & WEIGHT
265(W)x107(H)x312(D) mm, Approx.3kg

Tech Specs

LCR Meters / Impedance Measurement Products /LCR Meters Template

Type Benchtop
300 kHz
9999.99 mF
99.99 M Ohms
9999.99 H (9999990 mH)
Admittance (Y), Capacitance (C), Conductance (G), DC Resistance (Rdc), Dissipation Factor (D), Impedance (Z), Inductance (L), Phase Angle (θ), Quality Factor (Q), Reactance (X), Susceptance (B)
Yes
Graph Mode No
Yes
No
Warranty 2 YEARS
Safety Approval CE, UL
Interfaces I/O RS-232, USB Host
Storage Internal Memory, USB Flash Drive
Product Weight 6.61 LBS
Product Height 4.2 IN
Product Length 12.3 IN
Product Width 10.43 IN
Shipping Weight 10 LBS
Yes
HTS/Schedule B Number 9030.39.0100
ECCN Number 3A992
Calibration Included Factory Calibration
Power Supply Voltage 120V/220V Universal